物理工学コースからのおしらせ


R04年度 物理工学 談話会開催について

物理工学ユニットでは、以下のように談話会を開催させて頂きます(ハイブリッドを予定)。


講師:Prof. Montserrat Rivas(Department of Physics, Oviedo University, Spain)

演題:Magnetic nanoparticles and sensors for rapid diagnostic tests

日時:10月25日(火)16:15~17:15

場所:総合研究棟7階 W701室

オンライン視聴の際のZoomのミーティングIDは 937 3557 7465 です。
パスコードは、教員にお問い合わせください。

概要:
Lateral flow immunoassays for detecting biomarkers in body fluids are simple, quick, inexpensive point-of-care tests widely used in disease surveillance, such as during the coronavirus disease 2019 (COVID-19) pandemic. Improvements in sensitivity would increase their utility in healthcare, food safety, and environmental control. Recently, biofunctionalmagnetic nanoclusters have been used to selectively label target proteins, which allows their detection and quantification with a magneto-inductive sensor. This type of detector is easily integrated with the lateral flow immunoassay format. Pneumolysinis a cholesterol-dependent cytolysinand one of the most important protein virulence factors of pneumonia produced by Streptococcus pneumoniae. It is recognized as an important biomarker for diagnosis in urine samples. Pneumonia is the infectious disease that causes the most deaths globally, especially among children under five years and adults over 65 years, most of them in low-and middle-income countries. There especially, a rapid diagnostic urine test for pneumococcal pneumonia with high sensitivity and specificity would be helpful in primary care. In this work, a lateral flow immunoassay with magnetic nanoclusters conjugated to anti-pneumolysinantibodies was combined with two strategies to increase the technique’s performance. First, magnetic concentration of the protein before the immunoassay was followed by quantification by means of a mobile telephone camera, and the inductive sensor resulted in detection limits as low as 0.57 ng (telephone camera) and 0.24 ng (inductive sensor) of pneumolysinper millilitre. Second, magnetic relocation of the particles within the test strip after the immunoassay was completed increased the detected signal by 20%. Such results obtained with portable devices are promising when compared to non-portable conventional pneumolysindetection techniques such as enzyme-linked immunosorbent assays. The combination and optimization of these approaches would have excellent application in point-of-care biodetectionto reduce antibiotic misuse, hospitalizations, and deaths from community-acquired pneumonia.

<ポスターはこちらをご覧ください。

世話人:一柳 優子